Safety module XPSUAT33A3AP Telemecanique
XPS UAT33A3AP
|
1 pcs available immediately |
|
- Monitoring Safety switches, Emergency stop, Magnet, RFID, Safety light curtain, PNP,sensing mat/edges
- Connection Screw clamp terminals
- Number of safety circuits 3
- Additional outputs 1 pulsed telegram, 1 solid state
- Power supply 48…240 Vac / dc
|
308.80 CHF
|
|
Safety module XPSUDN13AC Telemecanique
XPS UDN13AC
|
Ø 7 - 15 working days (*) |
|
- Monitoring Safety switches, Emergency stop, Magnet, RFID, Safety light curtain, PNP
- Connection Spring terminals
- Number of safety circuits 12
- Additional outputs 1 pulsed telegram
- Power supply 24 Vac / dc
|
227.70 CHF
|
|
Safety module XPSUDN13AP Telemecanique
XPS UDN13AP
|
1 pcs available immediately |
|
- Monitoring Safety switches, Emergency stop, Magnet, RFID, Safety light curtain, PNP
- Connection Screw clamp terminals
- Number of safety circuits 12
- Additional outputs 1 pulsed telegram
- Power supply 24 Vac / dc
|
227.70 CHF
|
|
Safety module XPSUDN33AC Telemecanique
XPS UDN33AC
|
Ø 7 - 15 working days (*) |
|
- Monitoring Safety switches, Emergency stop, Magnet, RFID, Safety light curtain, PNP
- Connection Spring terminals
- Number of safety circuits 12
- Additional outputs 1 pulsed telegram
- Power supply 48…240 Vac / dc
|
248.10 CHF
|
|
Safety module XPSUDN33AP Telemecanique
XPS UDN33AP
|
Ø 7 - 15 working days (*) |
|
- Monitoring Safety switches, Emergency stop, Magnet, RFID, Safety light curtain, PNP
- Connection Screw clamp terminals
- Number of safety circuits 12
- Additional outputs 1 pulsed telegram
- Power supply 48…240 Vac / dc
|
248.10 CHF
|
|
Safety module XPSUEP14AC Telemecanique
XPS UEP14AC
|
Ø 7 - 15 working days (*) |
|
- Monitoring Extension safety contacts
- Connection Spring terminals
- Number of safety circuits without
- Additional outputs 2 NC
- Power supply 24 Vac / dc
|
129.90 CHF
|
|
Safety module XPSUEP14AP Telemecanique
XPS UEP14AP
|
1 pcs available immediately |
|
- Monitoring Extension safety contacts
- Connection Screw clamp terminals
- Number of safety circuits without
- Additional outputs 2 NC
- Power supply 24 Vac / dc
|
129.90 CHF
|
|
Safety module XPSUEP34AC Telemecanique
XPS UEP34AC
|
Ø 7 - 15 working days (*) |
|
- Monitoring Extension safety contacts
- Connection Spring terminals
- Number of safety circuits without
- Additional outputs 2 NC
- Power supply 48…240 Vac / dc
|
142.30 CHF
|
|
Safety module XPSUEP34AP Telemecanique
XPS UEP34AP
|
Ø 7 - 15 working days (*) |
|
- Monitoring Extension safety contacts
- Connection Screw clamp terminals
- Number of safety circuits without
- Additional outputs 2 NC
- Power supply 48…240 Vac / dc
|
142.30 CHF
|
|
Safety module XPSUS12AC Telemecanique
XPS US12AC
|
Ø 7 - 15 working days (*) |
|
- Monitoring Safety switches, Emergency stop, Magnet, RFID, Safety light curtain, PNP, Enabling switch
- Connection Spring terminals
- Number of safety circuits 4
- Additional outputs 1 pulsed telegram
- Power supply 24 Vac / dc
|
190.60 CHF
|
|
Safety module XPSUS12AP Telemecanique
XPS US12AP
|
1 pcs available immediately |
|
- Monitoring Safety switches, Emergency stop, Magnet, RFID, Safety light curtain, PNP, Enabling switch
- Connection Screw clamp terminals
- Number of safety circuits 4
- Additional outputs 1 pulsed telegram
- Power supply 24 Vac / dc
|
190.60 CHF
|
|
Safety module XPSUS32AC Telemecanique
XPS US32AC
|
Ø 7 - 15 working days (*) |
|
- Monitoring Safety switches, Emergency stop, Magnet, RFID, Safety light curtain, PNP, Enabling switch
- Connection Spring terminals
- Number of safety circuits 4
- Additional outputs 1 pulsed telegram
- Power supply 48…240 Vac / dc
|
210.40 CHF
|
|
Safety module XPSUS32AP Telemecanique
XPS US32AP
|
1 pcs available immediately |
|
- Monitoring Safety switches, Emergency stop, Magnet, RFID, Safety light curtain, PNP, Enabling switch
- Connection Screw clamp terminals
- Number of safety circuits 4
- Additional outputs 1 pulsed telegram
- Power supply 48…240 Vac / dc
|
210.40 CHF
|
|
Safety module XPSUVN11AC Telemecanique
XPS UVN11AC
|
Ø 7 - 15 working days (*) |
|
- Monitoring Zero speed detection (0,05...60s)
- Connection Spring terminals
- Number of safety circuits 3
- Additional outputs 1 pulsed telegram, 1 solid state
- Power supply 24 Vac / dc
|
376.20 CHF
|
|
Safety module XPSUVN11AP Telemecanique
XPS UVN11AP
|
Ø 7 - 15 working days (*) |
|
- Monitoring Zero speed detection (0,05...60s)
- Connection Screw clamp terminals
- Number of safety circuits 3
- Additional outputs 1 pulsed telegram, 1 solid state
- Power supply 24 Vac / dc
|
376.20 CHF
|
|
Safety module XPSUVN31AC Telemecanique
XPS UVN31AC
|
Ø 7 - 15 working days (*) |
|
- Monitoring Zero speed detection (0,05...60s)
- Connection Spring terminals
- Number of safety circuits 3
- Additional outputs 1 pulsed telegram, 1 solid state
- Power supply 48…240 Vac / dc
|
386.70 CHF
|
|
Safety module XPSUVN31AP Telemecanique
XPS UVN31AP
|
Ø 7 - 15 working days (*) |
|
- Monitoring Zero speed detection (0,05...60s)
- Connection Screw clamp terminals
- Number of safety circuits 3
- Additional outputs 1 pulsed telegram, 1 solid state
- Power supply 48…240 Vac / dc
|
386.70 CHF
|
|
Safety module XPSVNE1142P Telemecanique
XPS VNE1142P
|
1 pcs available immediately |
|
- Monitoring Zero speed detection (< 60 Hz )
- Connection fixed terminals
- Number of safety circuits 2
- Additional outputs 2 solid state
- Power supply 24 Vdc
|
623.20 CHF
|
|