FREE Shipping in Switzerland from CHF 50.00
Automation
Sensors
   
Brand
Kimo Instruments (135)
Category
Air quality (135)
Version
Single function (61)
Multifunction (74)
Measurement function
CO (15)
CO2 (10)
Humidity (10)
Temperature, Humidity (68)
Temperature (110)
CO2, Temperature (6)
Measuring range
0...500 ppm (5)
0...5'000 ppm (4)
5...95% RH (10)
-20...80°C | 5...95% RH (32)
0...50°C | 5...95% RH (16)
-20...80°C (64)
-100...400°C (5)
0...50°C (22)
-100...400°C | 0...100% RH (1)
0...50°C | 0...20'000 ppm (16)
-40...180°C | 5...95% RH (25)
Analogue output
PT100 (2)
1x 0...10 V (26)
1x 4...20 mA (23)
1x 0...10 V or 4...20 mA (3)
without (14)
2x 0...10 V (12)
2x 4...20 mA (58)
2x 4...20 mA or 0...10 V (47)
Switching output
without (74)
1x Relay (14)
2x Relay (47)
Power supply
without (2)
24 Vdc/ac (82)
24 Vdc (116)
110 / 230 Vac (17)
Display
without Display (59)
with Display (76)
Probe
Ambient (21)
Duct (8)
Remote, 2m (8)
Air tight (7)
Duct stainless steel, 100mm (5)
Terminal block (5)
Air tight (5)
2x PT100 (1)
Ambient + 1x PT100 (1)
Remote, 5m (9)
Remote, 10m (9)
Remote stainless steel 150mm, 5m (3)
Remote stainless steel 150mm, 10m (3)
Remote stainless steel 300mm, 5m (3)
Remote stainless steel 300mm, 10m (3)
Remote Plastic 150mm, 5m (3)
Remote Plastic 150mm, 10m (3)
Remote Plastic 300mm, 5m (3)
Remote Plastic 300mm, 10m (3)
Duct stainless steel, 150mm (5)
Duct stainless steel, 200mm (5)
Duct stainless steel, 250mm (5)
Duct stainless steel, 300mm (5)
Remote Plastic 150mm, 2m (3)
Remote Plastic 300mm, 2m (3)
Remote stainless steel 150mm, 2m (3)
Remote stainless steel 300mm, 2m (3)
Sort by:
Availability:
Hits: 135
Climatic transmitter TH110-AOES Kimo Instruments
TH110-AOES
Ø 15 - 25 working days (*)
  • Version Multifunction
  • Measurement function Temperature, Humidity
  • Measuring range 0...50°C | 5...95% RH
  • Analogue output 2x 0...10 V
  • Switching output without
  • Power supply 24 Vdc/ac
  • Display with Display
  • Probe Air tight
283.60 CHF
Climatic transmitter TH110-AOS Kimo Instruments
TH110-AOS
Ø 15 - 25 working days (*)
  • Version Multifunction
  • Measurement function Temperature, Humidity
  • Measuring range 0...50°C | 5...95% RH
  • Analogue output 2x 0...10 V
  • Switching output without
  • Power supply 24 Vdc/ac
  • Display with Display
  • Probe Ambient
260.60 CHF
Climatic transmitter TH110-PNA Kimo Instruments
TH110-PNA
Ø 7 - 15 working days (*)
  • Version Multifunction
  • Measurement function Temperature, Humidity
  • Measuring range -20...80°C | 5...95% RH
  • Analogue output 2x 4...20 mA
  • Switching output without
  • Power supply 24 Vdc
  • Display without Display
  • Probe Duct
248.20 CHF
Climatic transmitter TH110-PND Kimo Instruments
TH110-PND
Ø 15 - 25 working days (*)
  • Version Multifunction
  • Measurement function Temperature, Humidity
  • Measuring range -20...80°C | 5...95% RH
  • Analogue output 2x 4...20 mA
  • Switching output without
  • Power supply 24 Vdc
  • Display without Display
  • Probe Remote, 2m
248.20 CHF
Climatic transmitter TH110-PND-05M Kimo Instruments
TH110-PND-05M
Ø 15 - 25 working days (*)
  • Version Multifunction
  • Measurement function Temperature, Humidity
  • Measuring range -20...80°C | 5...95% RH
  • Analogue output 2x 4...20 mA
  • Switching output without
  • Power supply 24 Vdc
  • Display without Display
  • Probe Remote, 5m
264.10 CHF
Climatic transmitter TH110-PND-10M Kimo Instruments
TH110-PND-10M
Ø 15 - 25 working days (*)
  • Version Multifunction
  • Measurement function Temperature, Humidity
  • Measuring range -20...80°C | 5...95% RH
  • Analogue output 2x 4...20 mA
  • Switching output without
  • Power supply 24 Vdc
  • Display without Display
  • Probe Remote, 10m
278.40 CHF
Climatic transmitter TH110-PNES Kimo Instruments
TH110-PNES
Ø 15 - 25 working days (*)
  • Version Multifunction
  • Measurement function Temperature, Humidity
  • Measuring range 0...50°C | 5...95% RH
  • Analogue output 2x 4...20 mA
  • Switching output without
  • Power supply 24 Vdc
  • Display without Display
  • Probe Air tight
248.20 CHF
Climatic transmitter TH110-PNS Kimo Instruments
TH110-PNS
Ø 15 - 25 working days (*)
  • Version Multifunction
  • Measurement function Temperature, Humidity
  • Measuring range 0...50°C | 5...95% RH
  • Analogue output 2x 4...20 mA
  • Switching output without
  • Power supply 24 Vdc
  • Display without Display
  • Probe Ambient
223.40 CHF
Climatic transmitter TH110-POA Kimo Instruments
TH110-POA
Ø 15 - 25 working days (*)
  • Version Multifunction
  • Measurement function Temperature, Humidity
  • Measuring range -20...80°C | 5...95% RH
  • Analogue output 2x 4...20 mA
  • Switching output without
  • Power supply 24 Vdc
  • Display with Display
  • Probe Duct
283.60 CHF
Climatic transmitter TH110-POD Kimo Instruments
TH110-POD
Ø 7 - 15 working days (*)
  • Version Multifunction
  • Measurement function Temperature, Humidity
  • Measuring range -20...80°C | 5...95% RH
  • Analogue output 2x 4...20 mA
  • Switching output without
  • Power supply 24 Vdc
  • Display with Display
  • Probe Remote, 2m
283.60 CHF
Climatic transmitter TH110-POD-05M Kimo Instruments
TH110-POD-05M
Ø 15 - 25 working days (*)
  • Version Multifunction
  • Measurement function Temperature, Humidity
  • Measuring range -20...80°C | 5...95% RH
  • Analogue output 2x 4...20 mA
  • Switching output without
  • Power supply 24 Vdc
  • Display with Display
  • Probe Remote, 5m
299.70 CHF
Climatic transmitter TH110-POD-10M Kimo Instruments
TH110-POD-10M
Ø 15 - 25 working days (*)
  • Version Multifunction
  • Measurement function Temperature, Humidity
  • Measuring range -20...80°C | 5...95% RH
  • Analogue output 2x 4...20 mA
  • Switching output without
  • Power supply 24 Vdc
  • Display with Display
  • Probe Remote, 10m
313.80 CHF
Climatic transmitter TH110-POS Kimo Instruments
TH110-POS
Ø 7 - 15 working days (*)
  • Version Multifunction
  • Measurement function Temperature, Humidity
  • Measuring range 0...50°C | 5...95% RH
  • Analogue output 2x 4...20 mA
  • Switching output without
  • Power supply 24 Vdc
  • Display with Display
  • Probe Ambient
260.60 CHF
Climatic transmitter TH210-BNDI150-R Kimo Instruments
TH210-BNDI150-R
Ø 15 - 25 working days (*)
  • Version Multifunction
  • Measurement function Temperature, Humidity
  • Measuring range -40...180°C | 5...95% RH
  • Analogue output 2x 4...20 mA or 0...10 V
  • Switching output 2x Relay
  • Power supply 24 Vdc/ac
  • Display without Display
  • Probe Remote stainless steel 150mm, 2m
439.50 CHF
Climatic transmitter TH210-BNDI150-R-05M Kimo Instruments
TH210-BNDI150-R-05M
Ø 15 - 25 working days (*)
  • Version Multifunction
  • Measurement function Temperature, Humidity
  • Measuring range -40...180°C | 5...95% RH
  • Analogue output 2x 4...20 mA or 0...10 V
  • Switching output 2x Relay
  • Power supply 24 Vdc/ac
  • Display without Display
  • Probe Remote stainless steel 150mm, 5m
455.60 CHF
Climatic transmitter TH210-BNDI150-R-10M Kimo Instruments
TH210-BNDI150-R-10M
Ø 15 - 25 working days (*)
  • Version Multifunction
  • Measurement function Temperature, Humidity
  • Measuring range -40...180°C | 5...95% RH
  • Analogue output 2x 4...20 mA or 0...10 V
  • Switching output 2x Relay
  • Power supply 24 Vdc/ac
  • Display without Display
  • Probe Remote stainless steel 150mm, 10m
469.60 CHF
Climatic transmitter TH210-BNDI300-R Kimo Instruments
TH210-BNDI300-R
Ø 15 - 25 working days (*)
  • Version Multifunction
  • Measurement function Temperature, Humidity
  • Measuring range -40...180°C | 5...95% RH
  • Analogue output 2x 4...20 mA or 0...10 V
  • Switching output 2x Relay
  • Power supply 24 Vdc/ac
  • Display without Display
  • Probe Remote stainless steel 300mm, 2m
462.60 CHF
Climatic transmitter TH210-BNDI300-R-05M Kimo Instruments
TH210-BNDI300-R-05M
Ø 15 - 25 working days (*)
  • Version Multifunction
  • Measurement function Temperature, Humidity
  • Measuring range -40...180°C | 5...95% RH
  • Analogue output 2x 4...20 mA or 0...10 V
  • Switching output 2x Relay
  • Power supply 24 Vdc/ac
  • Display without Display
  • Probe Remote stainless steel 300mm, 5m
478.60 CHF
Climatic transmitter TH210-BNDI300-R-10M Kimo Instruments
TH210-BNDI300-R-10M
Ø 15 - 25 working days (*)
  • Version Multifunction
  • Measurement function Temperature, Humidity
  • Measuring range -40...180°C | 5...95% RH
  • Analogue output 2x 4...20 mA or 0...10 V
  • Switching output 2x Relay
  • Power supply 24 Vdc/ac
  • Display without Display
  • Probe Remote stainless steel 300mm, 10m
492.70 CHF
Climatic transmitter TH210-BNDP150-R Kimo Instruments
TH210-BNDP150-R
Ø 15 - 25 working days (*)
  • Version Multifunction
  • Measurement function Temperature, Humidity
  • Measuring range -40...180°C | 5...95% RH
  • Analogue output 2x 4...20 mA or 0...10 V
  • Switching output 2x Relay
  • Power supply 24 Vdc/ac
  • Display without Display
  • Probe Remote Plastic 150mm, 2m
398.80 CHF
  1 2 3 4 5 6 7  

         
Top brands at DigiParts Help About DigiParts Social Media
Telemecanique Ordering process and account About DigiParts Twitter
Crouzet Payment methods Legal information Facebook
Panasonic Delivery times Contact Youtube
Crydom Garantie General terms and cons  
Schneider Electric Shipping and delivery details  
Quintex Returning Articles  
     
(*) Due to the current Covid-19 situation there may be deviations in the indicated delivery times!
         
;